9-36 kW Three Phase, On-Line Double Conversion, UL924 Central Lighting Inverter

FirstLine PL/PLT 924

9-54 kW
Three Phase, On-Line Double Conversion, UL924 Central Lighting Inverter

Emergency Lighting System
FirstLine PL/PLT 924 is the result of your demand for an Emergency Lighting solution tailored to meet your requirements for a reliable, cost effective alternative for Emergency Lighting applications that help ensure the safety of your most important asset — your people. FirstLine PL/PLT 924 provides that solution with its easy-to-manage double conversion power electronics and battery system and its rugged all steel construction.
What is an Emergency Lighting Inverter?
The National Fire Protection Association (NFPA) has written Life Safety Code® (NFPA 101®*) that defines the requirements for emergency lighting for means of egress. The standard requires that emergency illumination shall be provided for not less than 1-1/2 hours (90 minutes) in the event of failure of normal lighting.  Installation and testing requirements are written in the National Electric Code® (NFPA 70®*). The FirstLine® PL/PLT 924 is a central system battery back-up to meet these requirements. In the event of an AC power failure, FirstLine® PL/PLT 924 automatically supports the connected lighting loads on battery power and will continue  to provide power without any interruption for a full 90 minutes.  When the utility power returns to normal, FirstLine®PL/PLT 924 will automatically recharge the batteries to be ready for the next power disturbance. In addition to meeting life safety requirements, the FirstLine®PL/PLT 924 can also increase the life expectancy of the protected lighting system and reduce long-term cost of ownership.

 


  • Compacto y Confiable
        o 9-54 kW prevé una huella más pequeña
        o Funcionamiento del refrigerador prolonga la vida útil de los componentes internos
  • Actuación de entrada CA
        o factor de potencia de entrada de alta de 0,99
        o entrada baja distorsión de la corriente de arranque suave
        o Poder función walk-in que garantiza rectificador progresiva puesta en marcha
  • IGBT y procesador de señal digital (DSP )
        o Reduce el impacto de la UPS en la oferta local
        o instalación simplifica donde hay capacidad de potencia limitada
  • entrada dual
        o de alimentación principal y de emergencia secundaria incremento de energía de reserva resiliencia de configuración individual o paralelo del sistema
  • Adaptable RSS cancelación
        o El control avanzado con tecnología de cancelación de avance AFC para baja distorsión armónica .
  • Seleccione Menú Display
        o Pantalla de uso fácil es fácil de ver y de uso intuitivo
  • Paralelo hasta 4 unidades
        o proporciona redundancia para aplicaciones de misión crítica sin hardware adicional
        o Kit paralelo , comunicación a través de tarjeta paralela CANBUS
  • Ahorro de instalación
        o Sistema llega con baterías de pre- montados y cableados de ahorro de costes laborales adicionales
  • Edificios Públicos
  • Teatros
  • Escuelas
  • Garajes
  • complejos de viviendas

Click Below to Remove Existing Filters

kW Rating: 36

kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 71.58 x 98.65 x 37.86
Weight (lbs.): 7809
Extras: 3 Gabinetes
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 52 x 23.15 x 32.96
Weight (lbs.): 584
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 52 x 23.15 x 32.96
Weight (lbs.): 1185
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 71.58 x 129.03 x 37.86
Weight (lbs.): 8249
Extras: 4 Gabinetes
kW Rating: 36
Output Voltage: 480Y/277
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 71.58 x 129.03 x 37.86
Weight (lbs.): 8299
Extras: 4 Gabinetes
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 71.58 x 114.64 x 37.86
Weight (lbs.): 7959
Extras: 4 Gabinetes
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 78.74 x 103.13 x 34.47
Weight (lbs.): 7519
Extras: 3 Gabinetes
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 659
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 691
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1093
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1109
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 480Y/277
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1379
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 929
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 480Y/277
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1199
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1199
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1230
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1770
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1633
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1649
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 480Y/277
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1919
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1469
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 480Y/277
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1739
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 72.41 x 23.13 x 34.47
Weight (lbs.): 1302
Extras: 1 Gabinete
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 78.74 x 103.13 x 34.47
Weight (lbs.): 7953
Extras: 3 Gabinetes
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 78.74 x 103.13 x 34.47
Weight (lbs.): 7969
Extras: 3 Gabinetes
kW Rating: 36
Output Voltage: 480Y/277
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 78.74 x 103.13 x 34.47
Weight (lbs.): 8239
Extras: 3 Gabinetes
kW Rating: 36
Output Voltage: 208Y/120
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 78.74 x 103.13 x 34.47
Weight (lbs.): 7789
Extras: 3 Gabinetes
kW Rating: 36
Output Voltage: 480Y/277
External Maintenance Bypass: no
Dimensions (H" x W" x D"): 78.74 x 103.13 x 34.47
Weight (lbs.): 8059
Extras: 3 Gabinetes

Elija su ubicación

Encuentre un distribuidor en su área.

map