10-40 kVA Three Phase, On-Line Double Conversion, Uninterruptable Power System

FirstLine PLT/FC

Frequency Converter 208 VAC, 50-60 kVA
Three phase Frequency Converter, 60Hz/50Hz for export product testing or operation of equipment rated at international frequency and voltage.

This product converts standard 208 VAC 60 Hz power to a selectable and precise 208 VAC +/- 2% 50 Hz power.  In the event of a power failure, the unit can be equipped with an internal or an optional battery cabinet to ride through a limited outage.

 


  • Up to 94% Efficient
    • Lower energy costs and carbon footprint
  • Compact & Reliable
    • 10-40 kVA internal batteries allow smaller footprint
    • Cooler operation extends internal component life
  • AC Input Performance
    • High input power factor of 0.99
    • Low input current distortion of <= 1% (THDi) @ full load
    • Soft Start Power walk-in function that ensures progressive rectifier start-up
  • IGBT and Digital Signal Processor (DSP)
    • Reduces the impact of the UPS on the local supply
    • Simplifies installation where there is limited power capacity
  • Dual Input
    • Main power and secondary emergency standby power increase resilience of single or parallel system configuration
  • Adaptive Feed Cancellation
    • Advanced control with AFC forward cancellation technology for low harmonic distortion
  • Menu Select Display
    • User friendly display is easy to see and intuitive to use
  • Parallel up to 4 Units
    • Provides redundancy for mission critical applications with no additional hardware
    • Parallel Kit, Communication through CANBUS Parallel Card
  • Operates as a precision Power Conditioner
    • -0 models can operate as a Power Conditioner upgradeable to a UPS in the future
  • Frequency Conversion
    • All units can be set as a 50/60 hZ Fequency Converter
  • Nationwide Service Program
    • Factory trained service personnel maximize equipment life
    • Full start-up service & preventive maintenance lowers cost of ownership
  • Full Two Year Warranty
  • Medical
  • Data Centers
  • Industrial Facilities
  • Education
  • Government

Load kVA: 10
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: No
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 410
Load kVA: 10
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: Yes
Battery Runtime: 37
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 950
Battery Runtime @ 100% Load (Internal): 37
Load kVA: 10
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: Yes
Battery Runtime: 18
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 735
Battery Runtime @ 100% Load (Internal): 18
Load kVA: 10
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: Yes
Battery Runtime: 9
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 630
Battery Runtime @ 100% Load (Internal): 9
Load kVA: 15
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: No
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 410
Load kVA: 15
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: Yes
Battery Runtime: 21
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 950
Battery Runtime @ 100% Load (Internal): 21
Load kVA: 15
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: Yes
Battery Runtime: 10
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 735
Battery Runtime @ 100% Load (Internal): 10
Load kVA: 15
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: Yes
Battery Runtime: 3
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 630
Battery Runtime @ 100% Load (Internal): 3
Load kVA: 20
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: No
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 410
Load kVA: 20
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: Yes
Battery Runtime: 14
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 950
Battery Runtime @ 100% Load (Internal): 14
Load kVA: 20
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: Yes
Battery Runtime: 6
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 630
Battery Runtime @ 100% Load (Internal): 6
Load kVA: 30
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: No
Dimensions (H" x W" x D"): 52 x 23.2 x 33
Weight (lbs.): 585
Load kVA: 30
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: Yes
Battery Runtime: 8
Dimensions (H" x W" x D"): 52 x 23.2 x 33
Weight (lbs.): 1125
Battery Runtime @ 100% Load (Internal): 8
Load kVA: 40
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: No
Dimensions (H" x W" x D"): 52 x 23.2 x 33
Weight (lbs.): 585
Load kVA: 40
Input and Output Voltage: 208/120
Internal Maintenance Bypass: Yes
Internal Batteries: Yes
Battery Runtime: 4
Dimensions (H" x W" x D"): 52 x 23.2 x 33
Weight (lbs.): 1185
Battery Runtime @ 100% Load (Internal): 4

Choose Your Location

Find a distributor in your area.

map

© 2022 Staco Energy Products Co. All Rights Reserved